Maximum Working Pressure Tables – Alloy 400 Annealed Seamless Tube (Nickel, Copper / ASTM B-165 or Equivalent)
Maximum Allowable Working Pressure (PSI) For Fractional Sizes
Tubing OD | Wall Thickness (Inches) | |||||||||||
.010 | .012 | .016 | .020 | .028 | .035 | .049 | .065 | .083 | .095 | .109 | .120 | |
1/16 | 6,422 | 7,872 | 10,768 | 13,484 | ||||||||
1/8 | 6,422 | 9,325 | 11,823 | |||||||||
3/16 | 4,081 | 5,935 | 7,630 | 11,005 | ||||||||
1/4 | 4,305 | 5,518 | 8,053 | 10,946 | ||||||||
3/8 | 3,530 | 5,107 | 7,029 | |||||||||
1/2 | 2,595 | 3,721 | 5,078 | 6,699 | ||||||||
5/8 | 2,051 | 2,927 | 3,970 | 5,200 | 6,056 | |||||||
3/4 | 1,696 | 2,412 | 3,259 | 4,249 | 4,933 | 5,755 | 6,422 | |||||
7/8 | 1,446 | 2,051 | 2,764 | 3,592 | 4,161 | 4,842 | 5,391 | |||||
1 | 5,040 | 7,140 | 9,595 | 12,445 | 14,390 | 16,715 | 18,585 |
Factor of Safety = 4, considering tensile strength to be 70,000 PSI at room temperature.
Maximum Allowable Working Pressure (Bar) For Metric Sizes
Tubing OD | Wall Thickness (Inches) | ||||||||||||
0.5 | 0.6 | 0.7 | 0.8 | 1.0 | 1.2 | 1.5 | 1.6 | 1.8 | 2.0 | 2.2 | 2.5 | 3.0 | |
3 | 464 | 567 | 672 | 775 | 965 | ||||||||
4 | 335 | 411 | 491 | 567 | 723 | 873 | |||||||
6 | 310 | 360 | 464 | 567 | 723 | 775 | |||||||
8 | 227 | 262 | 335 | 411 | 528 | 567 | |||||||
10 | 206 | 262 | 320 | 411 | 442 | ||||||||
12 | 169 | 215 | 262 | 335 | 360 | 411 | 464 | ||||||
14 | 182 | 222 | 282 | 303 | 345 | 389 | 433 | 500 | 612 | ||||
16 | 158 | 192 | 244 | 262 | 298 | 335 | 372 | 430 | 528 | ||||
18 | 140 | 169 | 215 | 230 | 262 | 294 | 326 | 377 | 464 | ||||
22 | 113 | 137 | 173 | 186 | 211 | 236 | 262 | 301 | 369 | ||||
25 | 99 | 120 | 152 | 162 | 184 | 206 | 228 | 262 | 320 |
Factor of Safety = 4, considering tensile strength to be 482.6 MPa at room temperature.
Information for reference purposes only. Corrosion Materials in not liable for any damages that may result from the use of this information.